NFPA CFPS Exam Syllabus Topics:

Topic Details
Topic 1
  • Detection and Alarm: In this topic, Fire protection consultants will need to demonstrate their expertise in the operational characteristics of fire alarm systems and detection technologies. They will be tested on their ability to apply relevant codes, inspect systems, and ensure compliance with safety standards.
Topic 2
  • Fire Prevention: Programs, Materials, Processes, and Environments: This topic assesses the capability of identifying fire hazards and applying mitigation strategies to minimize risks in a community or organization. Fire protection consultants will be tested on their ability to conduct safety audits, provide fire hazard training, and recommend safety tools and equipment.
Topic 3
  • Safety in the Built Environment: This topic will test the knowledge and skills of Fire protection consultants in evaluating and ensuring the proper application of fire protection systems in various buildings. They must demonstrate their ability to analyze fire safety protocols, building systems, and regulations for compliance.
Topic 4
  • Confining Fires: Fire protection consultants will be tested on their ability to recommend and ensure the proper installation and maintenance of fire-resistant construction, including firewalls and barriers. This section will assess their knowledge of smoke control methods and their ability to assist in the design of systems that limit fire spread, ensuring that buildings are equipped to confine fires and protect occupants.
Topic 5
  • Organizing for Fire and Rescue Services: This section will evaluate the skills of Fire protection consultants in pre-incident planning, incident command, and emergency service operations. They will be assessed on their ability to develop and implement an effective Incident Command System (ICS) and ensure fire and emergency services comply with regulations.
Topic 6
  • Information and Analysis for Fire Protection and Fire Science: In this section, Fire protection consultants will be evaluated on their ability to conduct fire loss investigations, fire analysis, and protection calculations. Their ability to assess fire dynamics and the impacts on building occupants is crucial for ensuring proper safety measures are in place.
Topic 7
  • Fire Suppression: This topic covers the knowledge of fire suppression systems, including routine maintenance, testing, and system design considerations. Fire protection consultants will be expected to demonstrate their ability to evaluate fire suppression systems, such as sprinklers and non-water-based systems, and ensure their proper functionality following codes and local policies.

 

Q113. The shape of the standard head discharge curve of a fire pump is determined by which of the following three limiting points?

 
 
 
 

Q114. Building codes should limit the size of an unsprinklered facility used for the processing and storage of Municipal Solid Waste built of type V construction to how many square feet?

 
 
 
 

Q115. What is the occupancy factor used by the Insurance Services Office (ISO) for computing required fire flow for C-3 (Combustible)?

 
 
 
 

Q116. Besides smoke detection what other permitted detection for Phase 1 elevate recall is typically used m ambient conditions?

 
 
 
 

Q117. In 1979, the phenomenon of convergence cluster formation in human fire behavior was identified in which of the following?

 
 
 
 

Q118. All of the following must be demonstrated to prove professional negligence under standard of care EXCEPT

 
 
 
 

Q119. The duration of required fire flow in public supply systems ranges from

 
 
 
 

Q120. Which of the following is one of the four fundamental fire safety goals?

 
 
 
 

Q121. What type of standpipe system provides 21/2 in. (65 mm) hose connections at designated locations in a building for use by the fire department?

 
 
 
 

Q122. On the Homeland Security color-coded threat-level system, what color code represents the most severe risk?

 
 
 
 

Q123. What class designation is given to a standpipe system consisting of a 2 . inch (6.35 cm) hose valve specifically for fire department use and a 1 . inch (3.81 cm) hose valve complete with hose and nozzles for building occupant use?

 
 
 
 

Q124. Which dry powder agent is suitable for extinguishing fires involving aluminum (AI)?

 
 
 
 

Q125. Which spacing multiplier is used for heat detectors installed in a building with a ceiling that is 15 ft (4.6 m) high?

 
 
 
 

Q126. What is the maximum allowable travel distance from any part of a smoke compartment to the door in a smoke barrier in a new health care facility?

 
 
 
 

Q127. The principle fuels used in a modern grain dryer are natural gas, vaporized liquid propane, and

 
 
 
 

Q128. Fire alarm visible appliance source intensity is measured in

 
 
 
 

Q129. Which type of plan review may provide information about a modification such as the removal of an abandoned underground flammable liquid tank?

 
 
 
 

Q130. When can the presence of chemical, biological, or radiological agents be ruled out?

 
 
 
 

Q131. in public operating mode how many decibels above the 24-hour average must the sonic pressure level (SPL) produced by a fire alarm system reach?

 
 
 
 

Q132. Between 1980-1998, the largest number of church structure fires in the U.S. was caused by which of the following?

 
 
 
 

Q133. NFPA 220 identifies which of the following as a construction type in which the structural elements are entirely of noncombustible or limited combustible materials permitted by the code and protected to have some degree of fire resistance for one hour?

 
 
 
 

Q134. Which system is used to communicate with public officials and the public so protective measures can be implemented?

 
 
 
 

Q135. Fire alarm systems utilize what three (3) basic types of circuits?

 
 
 
 

Q136. The standard that provides guidance for the selection of fire pumps is________.

 
 
 
 

Q137. A K-14 (200) spunkier flows what percent of a nominal K-5.6 (80) sprinkler?

 
 
 
 